Making Physiology Happen

Teaching

NS-AHKTA Add-on Neurobiology Teaching Set for AHK-TA

The NS-AHKTA add-on kit enables users of iWorx AHK-TA Combination Animal/Human Physiology Teaching kit to teach 7 experiments and 28 exercises for animal neurobiology.

Neurobiology Experiments
Note: The labs presented below are intended only for evaluation by prospective customers. iWorx users should refer to the User Area for the most current versions of labs and LabScribe Software.

The NS-AHKTA along with the AHK-TA enables the following experiments.

Animal Nerve Equipment Required
AN-01: Membrane Potentials IX-TA, IC-200
AN-02: Compound Action Potentials IX-TA, NBC-401 , IWIRE-B3G
AN-03: Neuromuscular Studies IX-TA, NBC-401 , IWIRE-B3G
AN-04: Action Potentials in Earthworm IX-TA, NBC-401 , IWIRE-B3G
AN-05: Cockroach Leg Mechanoreceptors IX-TA, C-ISO-N3 , IWIRE-B3G
AN-07: Cockroach Cercal Sense Organs IX-TA, iWire-B3G , C-MP-H2 , C-BNC-N2
AN-08: Frog Sciatic Nerve Compound Action Potential IX-TA, NA-100 , NBC-401
AN-09: Membrane Potentials - 3100 IX-TA, AM-3100
AN-10: Crustacean Stretch Receptors IX-TA, iWire-B3G , A-SUCTIONELEC
AN-11: Leech Central Nervous System IX-TA, AM-3100
AN-12A: Crustacean Neuromuscular Junction IX-TA, C-BNC-P2 , IWIRE-B3G , IC-200 , A-SUCTIONELEC
AN-12B: Neuromuscular Junction in Crayfish - part B IX-TA, C-BNC-P2 , IWIRE-B3G , IC-200 , A-SUCTIONELEC
AN-13: Crayfish Motor Nerve IX-TA, iWire-B3G , A-SUCTIONELEC
Human Nerve Equipment Required
HN-01: Auditory and Visual Reflexes IX-TA, EM-220
HN-02A: Stretch Receptors and Reflexes with Reflex Hammer IX-TA, PRH-200
HN-02B: Stretch Receptors and Reflexes with Plethysmograph IX-TA, PT-104
HN-03: Human Nerve Conduction Velocity IX-TA, iWire-B3G , C-HVS-SL2
HN-04: Hand vs. Foot Reactions IX-TA, EM-220 , FRS-100
HN-05: Visual Reflexes and Color Stimulation IX-TA, EM-220 , BCL-100
HN-06: Hoffman Reflex using the Soleus Muscle IX-TA, iWire-B3G , C-HVS-SL2
HN-07: Median Nerve Conduction Velocity IX-TA, iWire-B3G , C-HVS-SL2
HN-08: Game Show Physiology IX-TA, PT-104 , EM-220
Human PsychoPhysiology Equipment Required
HP-01: The Electroencephalogram (EEG) IX-TA,
HP-01A: The Electroencephalogram (EEG) using Button Electrodes IX-TA, C-ISO-SC5
HP-02: Galvanic Skin Response and Emotion IX-TA, iWire-B3G , C-ISO-GSR
HP-03: Galvanic Skin Response and Deception, Coginitive Compliance and Vigilance IX-TA, iWire-B3G , C-ISO-GSR
HP-04: Skin Temperature, Stress, Calming and Embarrassment IX-TA, TM-220 , iWire-B3G , C-ISO-GSR
HP-05A: Heart Rate and Blood Pressure IX-TA, PT-104 , BP-220
HP-05B: Personality and Vagal Tone IX-TA, PT-104 , RM-204
HP-05C: Vigilance and Reaction Time IX-TA, PT-104 , EM-220
HP-06: Cynicism-Hostility and the Hot Reactor IX-TA, PT-104 , BP-220
HP-07: The Stroop Effect IX-TA, PT-104 , IWIRE-B3G , C-ISO-GSR
HP-08: The Galvanic Skin Response (GSR) and Investigation into Cheating IX-TA, iWire-B3G , PT-104 , C-ISO-GSR
HP-09: Facial Expression Electromyograms (EMG) and Emotion IX-TA, iWire-B3G
HP-10: Visual Evoked Potentials (VEP) IX-TA, iWire-B3G
HP-11: Multisensory Reaction Times IX-TA, C-HVS-SL2
HP-12: Rubber Hand Illusion IX-TA, iWire-B3G , C-ISO-GSR , TM-220 , PT-104
HP-13: The Gaze Cue Paradigm IX-TA, EM-220
HP-14: Hypothesis-driven Biofeedback Lab/Research Study IX-TA, iWire-B3G , C-ISO-GSR , PT-104 , BP-220 , RM-204 , TM-220
HP-16: Eriksen Flanker Test IX-TA, EM-220 , EM-220
HP-17: Levels of Processing and Memory IX-TA, EM-220 , EM-220 , RPD-400 (opt)
HP-18: Posner Attention Test IX-TA, iWire-B3G , EM-220 , iTrax (opt)
HP-19: Lexical Decision Task IX-TA, EM-220 , EM-220 , RPD-400 (opt)
 

Part Number: NS-AHKTA

The NS-AHKTA kit includes: