Shopping Cart

Products

IX-BIO4 4-Channel Biopotential Recording Module

Overview

The IX-BIO4 is a Four Channel Biopotential Amplifier that allows multiple channels of EMG, ECG, EOG to be recorded simultaneously from a single exercising or resting subject. The recorder is furnished with LabScribe Recording and Analysis Software and connect sdirectly to a USB port on either a Macintosh or Windows PC.

EMG:

Kinesiology is the study of human and nonhuman animal-body movements, performance, and function by applying the sciences of biomechanics, anatomy, physiology, psychology, and neuroscience. When studying kinesiology,  surface electromyography  (sEMG or Surface EMG) is the measurement of choice.  The IX-BIOx enables 4/8 channels of EMG recordings, or a combination of EMG and ECG recordings.

Perform MVC calculations in LabScribe.

EMG analysis using LabScribe

ECG:

ECG signals can be measured with the IX-BIOx.  Measuring 2 channels of ECG, Lead I and Lead II allows LabScribe to calculate Lead III, aVR, aVF and aVL .  EMG signals can be measured at the same time as the ECG signals.

Application note on using the IX-BIO4 for recording 6 lead Rat ECG.

Analysing ECG’s recorded in LabScribe with Kubios HRV

Temperature:

In addition to measuring Bio-Potentials, each channel is also capable of measuring temperature using the TM-BIO temperature sensor.

Event Marker:

In addition to measuring Bio-Potentials, the Bio-channel is also capable of marking events using the EM-BIO Event Marker.

Experiment Builder:

Use the stimulus presentation capabilities of LabScribe software, to show an image, play a sound or a video file, while recording physiological parameters from the subject. Details…

 

Specs

Specifications
Analog Inputs4 Biopotential
Input Range2400mV, 1200mV, 800mV,
400mV, 200mV, 100mV,
50mV, 25mV, 12mV
A/D Converter
Sampling Speed20k Samples/sec per channel simultaneous
Resolution16 Bit
System noise< 6 microVolts
InterfaceUSB
General
EnclosurePlastic
PowerUSB
Warranty and UpgradesProtected by a 3 year warranty

Citations

Papers about ECG using iWorx systems on GoogleScholar

Papers about EMG using iWorx systems on GoogleScholar

Citations for IX-BIO4 and IX-BIO8:

Craighead, Daniel H., et al. "Ingestion of TRP channel agonists attenuates exercise‐induced muscle cramps." Muscle & Nerve (2017).

Looney, David P., et al. "Electromyographical and Perceptual Responses to Different Resistance Intensities in a Squat Protocol: Does Performing Sets to Failure With Light Loads Produce the Same Activity?." The Journal of Strength & Conditioning Research30.3 (2016): 792-799.

Flanagan, Shawn D., et al. "Concurrent Validity of the Armour39 Heart Rate Monitor Strap." The Journal of Strength &Conditioning Research 28.3 (2014): 870-873.

Earp, Jacob E., et al. "Regional Surface Electromyography of the Vastus Lateralis During Strength and Power Exercises." The Journal of Strength & Conditioning Research 30.6 (2016): 1585-1591.

 

 

 

 

 

 



Part Number: IX-BIO4

Manual: IX-BIO4