The IX-BIO4 is a Four Channel Biopotential Amplifier that allows multiple channels of EMG, ECG, EOG to be recorded simultaneously from a single exercising or resting subject. The recorder is furnished with LabScribe Recording and Analysis Software and connects directly to a USB port on either a Macintosh or Windows PC.
EMG:
Kinesiology is the study of human and nonhuman animal-body movements, performance, and function by applying the sciences of biomechanics, anatomy, physiology, psychology, and neuroscience. When studying kinesiology, surface electromyography (sEMG or Surface EMG) is the measurement of choice. The IX-BIOx enables 4/8 channels of EMG recordings, or a combination of EMG and ECG recordings.
Perform MVC calculations in LabScribe.
ECG:
ECG signals can be measured with the IX-BIOx. Measuring 2 channels of ECG, Lead I and Lead II allows LabScribe to calculate Lead III, aVR, aVF and aVL . EMG signals can be measured at the same time as the ECG signals.
Application note on using the IX-BIO4 for recording 6 lead Rat ECG.
Analysing ECG’s recorded in LabScribe with Kubios HRV
Experiment Builder:
Use the stimulus presentation capabilities of LabScribe software, to show an image, play a sound or a video file, while recording physiological parameters from the subject. Details…
Optional Addons:- Temperature measurement with TM-BIO temperature sensor.
- Mark events using the EM-BIO Event Marker.
- Measure range of motion with the GN-BIO goniometer
- Measure human respiration with the RM-BIO Respiration Monitor
- FRS-BIO: Foot Reaction Switch
- PRH-BIO: Patellar Reflex Hammer
- EIM-BIO: Emotional Intensity Meter
- ES-BIO : Electronic Stethoscope
- LS-BIO: Light Sensor
- PO2-100B: Pulse Oximeter with BNC outputs – finger sensor included
- PO2-CMS50D: USB Pulse-Oximeter
- Use the IA-100D with the C-BNC-MP2 to record data from any iWorx DIN8 transducer.
Human Heart
The Electrocardiogram and Peripheral Circulation
Exercise, the Electrocardiogram, and Peripheral Circulation
The Six-Lead Electrocardiogram
Human Muscle
Electromyogram Activity in Antagonistic Muscles
The Electrogastrogram (EGG) and the Growling Stomach
Electromyogram (EMG) Activity while Arm Wrestling
Electroculogram Activity (EOG)
Kinesiology and Electromyogram (EMG) Activity in Targeted Muscles
Psychological Physiology
- Dehkordi, Parastoo, et al. "Estimation of Cardiac Time Intervals From the Mechanical Activity of the Heart Using Machine Learning." 2019 Computing in Cardiology (CinC). IEEE, 2019.
- Zhu, Canzhan, et al. "Phloroglucinol averts isoprenaline hydrochloride induced myocardial infarction in rats." Drug development research (2019).
- Gottschall, Jinger S., Bryce Hastings, and Zachary Becker. "Muscle Activity Patterns Do Not Differ Between Push-Up and Bench Press Exercises." Journal of applied biomechanics(2018): 1-20.
- Craighead, Daniel H., et al. "Ingestion of TRP channel agonists attenuates exercise‐induced muscle cramps." Muscle & Nerve (2017).
- Looney, David P., et al. "Electromyographical and Perceptual Responses to Different Resistance Intensities in a Squat Protocol: Does Performing Sets to Failure With Light Loads Produce the Same Activity?." The Journal of Strength & Conditioning Research 30.3 (2016): 792-799.
- Flanagan, Shawn D., et al. "Concurrent Validity of the Armour39 Heart Rate Monitor Strap." The Journal of Strength & Conditioning Research 28.3 (2014): 870-873.
- Earp, Jacob E., et al. "Regional Surface Electromyography of the Vastus Lateralis During Strength and Power Exercises." The Journal of Strength & Conditioning Research 30.6 (2016): 1585-1591.
- Kh Dehkordi, Parastoo, et al. "Comparison of Different Methods for Estimating Cardiac Timings: A Comprehensive Multimodal Echocardiography Investigation." Frontiers in physiology 10 (2019): 1057.
Part Number: IX-BIO4
Manual: IX-BIO4
Specifications | |
Analog Inputs | 4 Biopotential |
Input Range | 2400mV, 1200mV, 800mV, 400mV, 200mV, 100mV, 50mV, 25mV, 12mV |
A/D Converter | |
Sampling Speed | 20k Samples/sec per channel simultaneous |
Resolution | 16 Bit |
System noise | < 6 microVolts |
Interface | USB |
General | |
Enclosure | Plastic |
Power | USB |
Warranty | Protected by a 3 year warranty |