Making Physiology Happen

Products

IX-BIO8 8-Ch Isolated Biopotential Recorder

Overview

The IX-BIO8 is an eight Channel Biopotential Amplifier that allows multiple channels of EMG, ECG, EOG to be recorded simultaneously from a single exercising or resting subject. The recorder is furnished with LabScribe Recording and Analysis Software and connects directly to a USB port on either a Macintosh or Windows. The recorder is connected to the subject by snap-leads to pre-gelled Ag/AgCl electrodes.

Features:

  • Portable, USB powered
  • Color coded leads
  • Easy export
  • Built in Journal for creating reports

EMG:

Kinesiology is the study of human and nonhuman animal-body movements, performance, and function by applying the sciences of biomechanics, anatomy, physiology, psychology, and neuroscience. When studying kinesiology,  surface electromyography  (sEMG or Surface EMG) is the measurement of choice.  The IX-BIOx enables 4/8 channels of EMG recordings, or a combination of EMG and ECG recordings.

Strength and performance testing and evaluation in athletes of all types can be performed with the IX-BIO8.

Perform MVC calculations in LabScribe.

EMG analysis using LabScribe

ECG:

ECG signals can be measured with the IX-BIOx.  Measuring 2 channels of ECG, Lead I and Lead II allows LabScribe to calculate Lead III, aVR, aVF and aVL .  EMG signals can be measured at the same time as the ECG signals.

Application note on using the IX-BIO8 for recording 6 lead Rat ECG.

Analysing ECG’s recorded in LabScribe with Kubios HRV

Experiment Builder:

Use the stimulus presentation capabilities of LabScribe software, to show an image, play a sound or a video file, while recording physiological parameters from the subject. Details…

Optional Addons:
  • Temperature measurement with  TM-BIO temperature sensor.
  • Mark events using the EM-BIO Event Marker.
  • Measure range of motion with the GN-BIO goniometer
  • Measure human respiration with the RM-BIO Respiration Monitor
  • FRS-BIO: Foot Reaction Switch
  • PRH-BIO: Patellar Reflex Hammer
  • EIM-BIO: Emotional Intensity Meter
  • ES-BIO : Electronic Stethoscope
  • LS-BIO: Light Sensor
  • PO2-100B: Pulse Oximeter with BNC outputs – finger sensor included
  • PO2-CMS50D: USB Pulse-Oximeter
  • Use the IA-100D with the C-BNC-MP2 to record data from any iWorx DIN8 transducer.
Citations

Papers about ECG using iWorx systems on Google Scholar

Papers about EMG using iWorx systems on Google Scholar

Citations for IX-BIO4 and IX-BIO8:
  • Gottschall, Jinger S., Bryce Hastings, and Zachary Becker. "Muscle Activity Patterns Do Not Differ Between Push-Up and Bench Press Exercises." Journal of applied biomechanics(2018): 1-20.
  • Craighead, Daniel H., et al. "Ingestion of TRP channel agonists attenuates exercise‐induced muscle cramps." Muscle & Nerve (2017).
  • Looney, David P., et al. "Electromyographical and Perceptual Responses to Different Resistance Intensities in a Squat Protocol: Does Performing Sets to Failure With Light Loads Produce the Same Activity?." The Journal of Strength & Conditioning Research 30.3 (2016): 792-799.
  • Flanagan, Shawn D., et al. "Concurrent Validity of the Armour39 Heart Rate Monitor Strap." The Journal of Strength & Conditioning Research 28.3 (2014): 870-873.
  • Earp, Jacob E., et al. "Regional Surface Electromyography of the Vastus Lateralis During Strength and Power Exercises." The Journal of Strength & Conditioning Research 30.6 (2016): 1585-1591.



Part Number: IX-BIO8

Manual: IX-BIO8

 Specifications
Analog Inputs 8 Biopotential
Input Range 2400mV, 1200mV, 800mV, 400mV, 200mV, 100mV, 50mV, 25mV, 12mV
A/D Converter
Sampling Speed 20k Samples/sec per channel simultaneous
Resolution 16 Bit
System Noise < 6 microVolts
Interface USB full speed
General
Enclosure Plastic
Certification CE
Power USB
Warranty Protected by a 3 year warranty
Software LabScribe