Shopping Cart
Making Physiology Happen
Call Us

Teaching

UHK-TA Ultimate Human Physiology Teaching Kit

The UHK-TA Ultimate Human Physiology Teaching Kit includes all of the necessary hardware and components, LabScribe software and expertly written courseware to teach 59 experiments and more than 175 exercises in cardiovascular, respiratory, and neuromuscular physiology.

Customer Testimonial

iWorx Human Physiology laboratory exercises are keyed to the HAPS Learning Goals and Outcomes.View iWorx Learning Goals and Outcomes
Courseware
These Lab Exercises can be performed with the UHK-TA kit. For additional exercises please visit the courseware page

Human Circulation
HC-01:Blood Pressure, Peripheral Circulation and Body Position
HC-02:Blood Pressure, Peripheral Circulation and Imposed Conditions
HC-03:Pulse Wave Velocity
HC-04:Pulse Contour Analysis
HC-05:Body Position, Exercise and Cardiac Output
HC-06C:Effects of Temperature on Peripheral Oxygen Saturation Levels
HumanExercise
HE-01:Metabolism and Thermal Response to Exercise
HE-02:Recovery from Exercise
HE-03C:Exercise, Blood Pressure and Oxygen Saturation Levels
Human Heart
HH-01:Electrocardiogram (ECG) and Peripheral Circulation
HH-02:ECG and Heart Sounds with Stethoscope
HH-03:Exercise, the ECG and Peripheral Circulation
HH-04:Six Lead ECG
HH-05A:The Diving Reflex
HH-05B:The Diving Reflex with Respiration rate
HH-06:Heart Rate Variability
HH-08:Auscultation
HH-12:Pulse and Heart Rate Variability (HRV)
Human Muscle
HM-01:Grip Strength and the Electromyogram
HM-02:Electromyogram Activity in Antagonistic Muscles
HM-03:Oculomotor Muscle Activity
HM-04:Stimulus Response, Work, Summation and Tetanus in Human Muscles
HM-08:Electromyogram (EMG) Activity while Arm Wrestling
HM-09:Kinesiology and Electromyogram (EMG) Activity in Targeted Muscles
HM-10:The Electrogastrogram (EGG) and Growling Stomach
HM-11:Electromyogram (EMG) for Paired Arm Wrestling
Human Nerve
HN-01:Auditory and Visual Reflexes
HN-02A:Stretch Receptors and Reflexes with Reflex Hammer
HN-02B:Stretch Receptors and Reflexes with Plethysmograph
HN-03:Human Nerve Conduction Velocity
HN-06:Hoffman Reflex using the Soleus Muscle
HN-07:Median Nerve Conduction Velocity
HN-08:Game Show Physiology
Human PsychoPhysiology
HP-02:Galvanic Skin Response and Emotion
HP-03:Galvanic Skin Response and Deception, Coginitive Compliance and Vigilance
HP-04:Skin Temperature, Stress, Calming and Embarrassment
HP-05A:Heart Rate and Blood Pressure
HP-05B:Personality and Vagal Tone
HP-05C:Vigilance and Reaction Time
HP-06:Cynicism-Hostility and the Hot Reactor
HP-07:The Stroop Effect
HP-08:The Galvanic Skin Response (GSR) and Investigation into Cheating
HP-09:Facial Expression Electromyograms (EMG) and Emotion
HP-10:Visual Evoked Potentials (VEP)
HP-11:Multisensory Reaction Times
HP-12:Rubber Hand Illusion
HP-13:The Gaze Cue Paradigm
HP-14:Hypothesis-driven Biofeedback Lab/Research Study
HP-16:Eriksen Flanker Test
Human Spirometry
HS-01:Breathing Parameters at Rest and After Exercise
HS-02:Breathing and Gravity
HS-03:Factors that Affect Breathing Patterns
HS-04:Lung Volumes and Heart Rate
HS-05:Breathing Techniques and Heart Rate
HS-06C:Ventilation and Oxygen Saturation Levels – Part 1
HS-07C:Ventilation and Oxygen Saturation Levels – Part 2
HS-08:Restrictive and Obstructive Airway Diseases
Tutorial
TT-01:Tutorial with ECG
TT-02:Tutorial with pulse

 



Part Number: UHK-TA

The kit includes:
  • IX-TA-220: iWorx TA Recorder with built-in Spirometer, Heart Sounds Sensor, GripForce/Blood Pressure Sensor, Temperature Sensor, O2 Electrode Input,two iWire Digital Interfaces, High and Low Voltage Stimulators.
  • LabScribe Software with site license and free updates.
  • iWire-B3G Isolated ECG and EMG iWire Recording Module.
  • A-BNC-HP: HeadPhone.
  • A-FH-300: Spirometry - Re-useable Flow Head 300L.
  • BP-220: Blood Pressure Cuff and valve .
  • C-HVS-SL2: Stimulator Cable - Set 2 (Red and Black) Safety to Snap-Lead.
  • C-ISO-GSR: GSR Finger Electrodes (Set of Two) for iWire-B3G Recording Module.
  • C-ISO-SC7: EEG Silver-SilverChloride Cup electrodes.
  • C-ISO-SL7: Recording Leads - 7 Safety Pin to Snap Connectors.
  • C-USB: USB Cable.
  • EM-220: Event Marker with Phono Connector
  • FT-220: Hand Dynamometer with A-BT-220 Tubing .
  • GN-100: Single-Axis Goniometer.
  • HSM-220: Stethoscope and tubing .
  • PO2-CMS50D: USB Pulse Oximeter (Includes finger sensor) .
  • PRH-200: Patellar Reflex Hammer.
  • PT-104: Pulse Plethysmograph (piezo crystal).
  • RM-204: Respiration Monitor (piezo crystal)
  • SMT-220: Striated Muscle Transducer
  • TM-220: Temperature Probe.
  • A-GC-7165: Disposable Adult Electrodes - 150 per package.
  • A-GSR-GEL: Skin Resistance/Conductance Electrode Paste.
  • A-KB-TA: Kit Box for HK-TA.
  • A-SRK-1: Student Respiration Kit.
  • A-ST-300-TA: Spirometer Silicon Tubing with red and white luer fittings .
  • A-UP12-DC-25-1.5A: Univ. 12VDC Power Supply for IX-TA.
Optional Addon Kits:
List of all transducers compatible with the IX-TA-220