IX-BIO4-SA Small Animal ECG/EMG System

The IX-BIO4-SA system is optimized for small animals.

The IX-BIO4-SA system includes:

The IX-BIO4 is a Four Channel Biopotential Amplifier that allows multiple channels of EMG, ECG, EOG to be recorded simultaneously from a single subject. The recorder is furnished with LabScribe Recording and Analysis Software and connects directly to a USB port on either a Macintosh or Windows PC.

IX-BIO8-SA is a 8 channel system.


ECG

ECG signals can be measured with the IX-BIOx.  Measuring 2 channels of ECG, Lead I and Lead II allows LabScribe software to calculate Lead III, aVR, aVF and aVL .  EMG signals can be measured at the same time as the ECG signals.

White Papers:

Application note on using the IX-BIO4-SA for recording 6 lead Rat ECG.

Analysing ECG’s recorded in LabScribe with Kubios HRV

Videos


EMG

Kinesiology is the study of human and nonhuman animal-body movements, performance, and function by applying the sciences of biomechanics, anatomy, physiology, psychology, and neuroscience. When studying kinesiology,  surface electromyography  (sEMG or Surface EMG) is the measurement of choice.  The IX-BIOx enables 4 channels of EMG recordings, or a combination of EMG and ECG recordings.

White Papers

Perform MVC calculations in LabScribe.

EMG analysis using LabScribe


Citations

Papers about ECG using iWorx systems on Google Scholar

Papers about EMG using iWorx systems on Google Scholar

Citations for IX-BIO4 and IX-BIO8:
  • Gottschall, Jinger S., Bryce Hastings, and Zachary Becker. "Muscle Activity Patterns Do Not Differ Between Push-Up and Bench Press Exercises." Journal of applied biomechanics(2018): 1-20.
  • Craighead, Daniel H., et al. "Ingestion of TRP channel agonists attenuates exercise‐induced muscle cramps." Muscle & Nerve (2017).
  • Looney, David P., et al. "Electromyographical and Perceptual Responses to Different Resistance Intensities in a Squat Protocol: Does Performing Sets to Failure With Light Loads Produce the Same Activity?." The Journal of Strength & Conditioning Research30.3 (2016): 792-799.
  • Flanagan, Shawn D., et al. "Concurrent Validity of the Armour39 Heart Rate Monitor Strap." The Journal of Strength &Conditioning Research 28.3 (2014): 870-873.
  • Earp, Jacob E., et al. "Regional Surface Electromyography of the Vastus Lateralis During Strength and Power Exercises." The Journal of Strength & Conditioning Research 30.6 (2016): 1585-1591.

 



Part Number: IX-BIO4-SA

Specifications
Analog Inputs4 Biopotential
Input Range2400mV, 1200mV, 800mV, 400mV, 200mV, 100mV, 50mV, 25mV, 12mV
A/D Converter
Sampling Speed20k Samples/sec per channel simultaneous
Resolution16 Bit
System noise< 6 microVolts
InterfaceUSB
General
EnclosurePlastic
PowerUSB
Warranty 3 years