RS-IBP4, 4 Channel Invasive Blood Pressure System, is designed for measuring Invasive Blood pressure in small and large animals, such as: mice, rats, squirrels, prairie dogs, porcupines, beavers, guinea pigs, hamsters, rabbits, hares, pigs, sheep, dogs, cows, etc.

The blood pressure transducer can also be positioned outside the cage and connected to a freely-moving rodent with a fluid swivel and tether system.

RS-IBP4 system includes

Bladder Pressure
The BP-100/102 blood pressure transducer can also be used to measure bladder pressure.

Software

LabScribe Blood Pressure Module

LabScribe Blood Pressure Module

LS-30BP The LabScribe Blood Pressure Module acquires and analyzes data from blood pressure transducers. Data can be analyzed from ventricular and arterial signals in real-time.
The software automatically calculates common indices of function from the blood pressure signal where it can easily be exported to another program for further analysis.

Arterial Pressure Calculations:Ventricular Pressure Calculations:
  • Heart Rate (HR)
  • Maximum Pressure (Pmax)
  • Minimum Pressure (Pmin)
  • Mean Arterial Pressure (MAP)
  • Systolic and diastolic pressure
  • Maximum dP/dt (dP/dtmax)
  • Minimum dP/dt (dP/dtmin)
  • Pulse Height
  • Notch Pressure
  • Systolic Duration
  • Diastolic Duration
  • Cycle Duration
  • Time To Peak
  • Election Time
  • Percent Recovery
  • Heart Rate (HR)
  • Maximum Pressure (Pmax)
  • Minimum Pressure (Pmin)
  • Mean Pressure (Pmean)
  • End-systolic Pressure (Pes)
  • End-diastolic Pressure (Ped)
  • Maximum dP/dt (dP/dtmax)
  • Minimum dP/dt (dP/dtmin)
  • Developed Pressure
  • dP/dt@
  • Contractility Index
  • Relaxation Index
  • Systolic Duration
  • Diastolic Duration
  • Cycle Duration
  • Tension Time Index
  • Relaxation Time
  • Isovolumetric Time
  • Tau (Weiss, Logistic, Glantz, Mirsky)
Detailed information about using the modules is in the LabScribe Manual

Components

Transducers
BP-100 ProbeBP-100  Intravascular Blood Pressure Probe
Measures direct arterial or venous pressure in animals.BP-100RE Replacement Element for BP-100 Probe
BP-102 Transducer

 

BP-102  Blood Pressure Transducer
With integral 3cc flush device and stopcock, can be used to measure
direct arterial or venous pressure in animals.
IX-RA-834 RecorderIX-RA-834 Recorder
The iWorx RA Recorder is the foundation for iWorx advanced research systems. It include 4 transducer inputs, for recording 4 channels of Blood Pressure. Additional 4 channels of Blood Pressure can be recorded using the IA-400D amplifier and the 4 BNC inputs of the IX-RA-834.  IX-RA-834 provides the ease of use and flexibility to speed your research.

 



Part Number: RS-IBP4